Non-Isolated DC/DC Converters |Sanken Electric

日本語English中文(简体)

Refine Search

 
Part NumberPurchase
Online
Data sheetstatusPackageMinimum Input Voltage
(V)
Maximum Input Voltage
(V)
Minimum Output Voltage
(V)
Maximum Output Voltage
(V)
Output Voltage
(V)
Output Current
(A)
Operating FrequencySynchronous / AsynchronousOvercurrent ProtectionThermal ProtectionUVLOSoft StartPart Number
BR200 In Production Surface Mount Type(20.32×11.43×4.2mm) 7 14 0.75 1.65 10 300kHz Synchronous Hiccup NO NO YES BR200
BR202 In Production Surface Mount Type(33.02×13.46×4.2mm) 9.0 13.2 0.75 1.65 20 300kHz Synchronous Hiccup NO NO YES BR202
BR203 In Production Surface Mount Type(33.02×13.46×4.2mm) 9.0 13.2 1.6 5.5 20 400kHz Synchronous Hiccup NO NO YES BR203
BR204 In Production Surface Mount Type(20.32×11.43×4.2mm) 10.8 13.2 1.6 5.5 10 600kHz Synchronous Hiccup NO NO YES BR204
BR205 In Production Surface Mount Type(20.32×11.43×4.2mm) 4.5 7 0.75 3.63 10 600kHz Synchronous Hiccup NO NO YES BR205
BR206 In Production Surface Mount Type(33.02×13.46×4.2mm) 4.5 7 0.75 3.63 20 400kHz Synchronous Hiccup NO NO YES BR206
BR300 In Production Thru-hole 8 30 5 1 350kHz Asynchronous Drooping Type NO NO YES BR300
BR301 In Production Thru-hole 8 30 3.3 1 350kHz Asynchronous Drooping Type NO NO YES BR301